Acquisition¶
Use this tab to configure complete multi-dimensional acquisition sequences across all available dimension modules.
To set up a multi-dimensional acquisition:
- Select the required dimension(s) from the panel.
- Choose the appropriate data processor.
- Specify the save directory for the output files.
- Edit a description of your experiment.
- a. Click Generate to add acquisition sequence description and/or Write your own experiment description.
- b. Confirm to close the window.
- Launch the acquisition.
Note
The interface varies depending on the microscope system hardware, particularly the available dimensions.
All dimensions share a consistent interface. The UI controls for configuring dimensions include:
| Icon | Description |
|---|---|
| Inactive: The sequence excludes the dimension. Click to activate. | |
| Active: The sequence includes the dimension. Click to deactivate. | |
| Configured: The dimension's parameters are set. Here, 11 images will be acquired for this dimension. | |
| Edit: Click to configure the dimension settings. | |
| Reorder: Drag and drop to change the dimension execution order. The dimension order defines the nesting loop of the sequence, executing from top to bottom. |
Dimension Execution Order¶
The order of the active dimensions dictates the nested loop structure of the acquisition sequence. Use the Reorder handle to drag and drop dimensions to change their execution order.
Dimensions at the top of the list act as the outer loops of the sequence, progressing more slowly. Dimensions positioned lower in the list act as the inner loops, executing more frequently. For example, if Time is placed above Channels, the system acquires all channels for a single time point before progressing to the next time point. Conversely, if Channels is placed above Time, the system acquires the entire time-lapse sequence for the first channel before switching to the next channel. Permuting these dimensions correctly is critical, as it directly determines how the hardware coordinates the image acquisition.
MDA Configuration¶
Use the MDA Configuration window to choose which dimensions are available in the acquisition sequence, rename them, assign motorized devices to the spatial axes, and define additional custom dimensions.
To open the window, click Config in the sequence header of the Acquisition > MDA tab (next to Add and Show All).
The window contains three sections:
- Dimension Name (1): Select the dimensions available in the sequence and set their labels. See Dimension Name.
- Axis Editor (2): Assign the motorized devices that drive the X, Y, and Z axes. See Selecting the Z Device (Axis Editor).
- Extra Dimensions (3): Define additional custom dimensions. See Extra Dimensions.
Click Confirm (4) to apply the changes, or Cancel (5) to discard them.
Dimension Name¶
The Dimension Name section lists the standard dimensions of the sequence: Time, Z-Stack, Multi-Positions, Tiling, Channels, Photomanipulation, Autofocus, Stabilization, and Python Script.
Each row contains a checkbox and a text field:
- Checkbox (1): Select it to make the dimension available in the sequence panel. Clear it to hide the dimension from the sequence.
- Name field (2): Enter the label displayed for the dimension in the sequence panel (for example, rename Multi-Channels to Fluorophores). The field is disabled when the checkbox is cleared.
The Channels Dimension row includes an additional drop-down list (3). Select the channel parameters to display as columns in the Multi-Channels dimension: Exposure, Z Stack, Z Offset, Shutter Blink, and Time Filter. By default, Exposure, Z Stack, and Time Filter are displayed.
Note
The list of rows depends on the system hardware and licensed options. For example, the Photomanipulation Dimension row appears only when a photomanipulation (FRAP) device is configured.
Important
A selected dimension is also hidden if the device it requires is missing from the Axis Editor. The Z-Stack dimension requires a Z Axis device. The Positions, Tiling, and Stabilization dimensions require both an X Axis and a Y Axis device.
The Stabilization dimension is a custom development that does not apply to most systems. Unless your system was specifically configured for stabilization, clear its checkbox to hide it from the sequence panel.
Selecting the Z Device (Axis Editor)¶
The Axis Editor defines which motorized device drives each spatial axis during the acquisition sequence. Use it to change the device that controls focus (Z), for example to switch from the microscope internal Z-drive to a piezo Z stage.
To select the Z device:
- Open the MDA Configuration window.
-
Locate the Axis Editor section below the list of dimensions.
-
In the Z Axis drop-down list (1), select the device that drives focus. Only motorized devices with a numerical position, such as Z-drives and piezo stages, are listed.
- Click Confirm at the bottom of the MDA Configuration window to apply the configuration.
The X Axis and Y Axis drop-down lists (2) work the same way and define the devices that drive the stage axes.
The selected Z device applies to every dimension that moves the focus, including the Z-stack and the Z coordinate stored for each position.
Extra Axis
Click Add next to Extra Axis (3) to record additional devices, such as a second focus drive or a rotation stage, together with each saved position.
Tip
Click Reset (4) to restore the default X, Y, and Z devices defined for the system and to clear the Extra Axis list.
Important
By default, the Software Autofocus routine also uses the Z device selected in the Axis Editor. A different device selected in the autofocus advanced settings overrides this default for the autofocus routine only.
Extra Dimensions¶
Use the Extra Dimensions section to add custom dimensions to the sequence, in addition to the standard dimensions. Each Extra Dimension row contains:
- A type drop-down list (1), which defines how the dimension behaves.
- A device selector (2), displayed only for the types that drive a device.
- A Name field (3), which sets the label displayed for the dimension in the sequence panel.
The available types are:
| Type | Device selection | Description |
|---|---|---|
| MinMaxDimension | One device with a numerical position | Steps the selected device between two limits, in the same way as a Z-stack. Use it, for example, to scan a motorized device other than the Z drive. |
| MultiDeviceTableDimension | One or several devices | Acquires a table of presets. Each row of the table defines a combination of states for the selected devices. |
| PositionDimension | One stage | Adds a multi-position dimension driven by a second motorized stage. |
| TimeDimension | None | Adds a second time-lapse loop to the sequence. |
| RepetitionDimension | None | Repeats the nested dimensions a defined number of times. |
| SparqDimension | None | Listed only when the corresponding license option is enabled on the system. |
Click Confirm (4) to add the configured extra dimensions to the sequence panel. Configure and reorder them like the standard dimensions.
Note
A row with a device-based type is ignored if no device is selected. When you confirm, the software displays an error if a configured extra dimension cannot find its device or stage.