com.inscoper.nbo.ExcitationCalibration
Represents the XML element ExcitationCalibration . More...
Inherits from com.inscoper.nbo.IntensityCalibration_Type , com.inscoper.nbo.NBOBaseClass
Public Functions
Name
synchronized void
delete ()
ExcitationCalibration ()
String
getTypeName () Returns the class type name.
String
getXMLName () Returns the XML element name corresponding to this class.
ENBOType
getNBOType () Returns the NBO Type corresponding to this class.
NBOBaseClassVector
getChildren () Returns a list of all classes derived from this class.
NBOBaseClassVector
getSubElements () Returns a list of all child elements contained in this class.
void
fromJsonFile (String path, boolean validate) Populates this object from a JSON file.
void
fromJsonFile (String path) Populates this object from a JSON file.
void
fromJsonString (String json_string, boolean validate) Populates this object from a JSON string.
void
fromJsonString (String json_string) Populates this object from a JSON string.
void
fromXmlFile (String path, boolean validate) Populates this object from a XML file.
void
fromXmlFile (String path) Populates this object from a XML file.
void
fromXmlString (String xml_string, boolean validate) Populates this object from a XML string.
void
fromXmlString (String xml_string) Populates this object from a XML string.
void
toXmlFile (String filename, boolean validate) Serializes this object to an XML file.
void
toXmlFile (String filename) Serializes this object to an XML file.
String
toXmlString (boolean validate) Serializes this object to an XML string.
String
toXmlString () Serializes this object to an XML string.
void
setSpinningDiskInLightPath (boolean value, boolean validate) Sets the value of the SpinningDiskInLightPath attribute.
void
setSpinningDiskInLightPath (boolean value) Sets the value of the SpinningDiskInLightPath attribute.
boolean
getSpinningDiskInLightPath () Returns the value of the SpinningDiskInLightPath attribute.
void
resetSpinningDiskInLightPath () Resets the SpinningDiskInLightPath attribute to an unset state.
boolean
hasSpinningDiskInLightPath () Checks whether the SpinningDiskInLightPath attribute is present.
void
setNominalEx_Wavelength (float value, boolean validate) Sets the value of the NominalEx_Wavelength attribute.
void
setNominalEx_Wavelength (float value) Sets the value of the NominalEx_Wavelength attribute.
float
getNominalEx_Wavelength () Returns the value of the NominalEx_Wavelength attribute.
void
resetNominalEx_Wavelength () Resets the NominalEx_Wavelength attribute to an unset state.
boolean
hasNominalEx_Wavelength () Checks whether the NominalEx_Wavelength attribute is present.
void
setNominalEx_WavelengthUnit (UnitsLength_Type value, boolean validate) Sets the value of the NominalEx_WavelengthUnit attribute.
void
setNominalEx_WavelengthUnit (UnitsLength_Type value) Sets the value of the NominalEx_WavelengthUnit attribute.
UnitsLength_Type
getNominalEx_WavelengthUnit () Returns the value of the NominalEx_WavelengthUnit attribute.
void
resetNominalEx_WavelengthUnit () Resets the NominalEx_WavelengthUnit attribute to an unset state.
boolean
hasNominalEx_WavelengthUnit () Checks whether the optional NominalEx_WavelengthUnit attribute is present.
void
setObservedEx_Wavelength (float value, boolean validate) Sets the value of the ObservedEx_Wavelength attribute.
void
setObservedEx_Wavelength (float value) Sets the value of the ObservedEx_Wavelength attribute.
float
getObservedEx_Wavelength () Returns the value of the ObservedEx_Wavelength attribute.
void
resetObservedEx_Wavelength () Resets the ObservedEx_Wavelength attribute to an unset state.
boolean
hasObservedEx_Wavelength () Checks whether the ObservedEx_Wavelength attribute is present.
void
setObservedEx_WavelengthUnit (UnitsLength_Type value, boolean validate) Sets the value of the ObservedEx_WavelengthUnit attribute.
void
setObservedEx_WavelengthUnit (UnitsLength_Type value) Sets the value of the ObservedEx_WavelengthUnit attribute.
UnitsLength_Type
getObservedEx_WavelengthUnit () Returns the value of the ObservedEx_WavelengthUnit attribute.
void
resetObservedEx_WavelengthUnit () Resets the ObservedEx_WavelengthUnit attribute to an unset state.
boolean
hasObservedEx_WavelengthUnit () Checks whether the optional ObservedEx_WavelengthUnit attribute is present.
void
setPercentageNominalPowerSettings (float value, boolean validate) Sets the value of the PercentageNominalPowerSettings attribute.
void
setPercentageNominalPowerSettings (float value) Sets the value of the PercentageNominalPowerSettings attribute.
float
getPercentageNominalPowerSettings () Returns the value of the PercentageNominalPowerSettings attribute.
void
resetPercentageNominalPowerSettings () Resets the PercentageNominalPowerSettings attribute to an unset state.
boolean
hasPercentageNominalPowerSettings () Checks whether the PercentageNominalPowerSettings attribute is present.
void
setObservedIlluminationPowerAtBackOfObjective (float value, boolean validate) Sets the value of the ObservedIlluminationPowerAtBackOfObjective attribute.
void
setObservedIlluminationPowerAtBackOfObjective (float value) Sets the value of the ObservedIlluminationPowerAtBackOfObjective attribute.
float
getObservedIlluminationPowerAtBackOfObjective () Returns the value of the ObservedIlluminationPowerAtBackOfObjective attribute.
void
resetObservedIlluminationPowerAtBackOfObjective () Resets the ObservedIlluminationPowerAtBackOfObjective attribute to an unset state.
boolean
hasObservedIlluminationPowerAtBackOfObjective () Checks whether the ObservedIlluminationPowerAtBackOfObjective attribute is present.
void
setObservedIlluminationPowerAtBackObjectiveUnit (UnitsPower_Type value, boolean validate) Sets the value of the ObservedIlluminationPowerAtBackObjectiveUnit attribute.
void
setObservedIlluminationPowerAtBackObjectiveUnit (UnitsPower_Type value) Sets the value of the ObservedIlluminationPowerAtBackObjectiveUnit attribute.
UnitsPower_Type
getObservedIlluminationPowerAtBackObjectiveUnit () Returns the value of the ObservedIlluminationPowerAtBackObjectiveUnit attribute.
void
resetObservedIlluminationPowerAtBackObjectiveUnit () Resets the ObservedIlluminationPowerAtBackObjectiveUnit attribute to an unset state.
boolean
hasObservedIlluminationPowerAtBackObjectiveUnit () Checks whether the optional ObservedIlluminationPowerAtBackObjectiveUnit attribute is present.
void
setObseredIlluminationPowerAtSample (float value, boolean validate) Sets the value of the ObseredIlluminationPowerAtSample attribute.
void
setObseredIlluminationPowerAtSample (float value) Sets the value of the ObseredIlluminationPowerAtSample attribute.
float
getObseredIlluminationPowerAtSample () Returns the value of the ObseredIlluminationPowerAtSample attribute.
void
resetObseredIlluminationPowerAtSample () Resets the ObseredIlluminationPowerAtSample attribute to an unset state.
boolean
hasObseredIlluminationPowerAtSample () Checks whether the ObseredIlluminationPowerAtSample attribute is present.
void
setObseredIlluminationPowerAtSampleUnit (UnitsPower_Type value, boolean validate) Sets the value of the ObseredIlluminationPowerAtSampleUnit attribute.
void
setObseredIlluminationPowerAtSampleUnit (UnitsPower_Type value) Sets the value of the ObseredIlluminationPowerAtSampleUnit attribute.
UnitsPower_Type
getObseredIlluminationPowerAtSampleUnit () Returns the value of the ObseredIlluminationPowerAtSampleUnit attribute.
void
resetObseredIlluminationPowerAtSampleUnit () Resets the ObseredIlluminationPowerAtSampleUnit attribute to an unset state.
boolean
hasObseredIlluminationPowerAtSampleUnit () Checks whether the optional ObseredIlluminationPowerAtSampleUnit attribute is present.
void
setShortTermIlluminationStability (float value, boolean validate) Sets the value of the ShortTermIlluminationStability attribute.
void
setShortTermIlluminationStability (float value) Sets the value of the ShortTermIlluminationStability attribute.
float
getShortTermIlluminationStability () Returns the value of the ShortTermIlluminationStability attribute.
void
resetShortTermIlluminationStability () Resets the ShortTermIlluminationStability attribute to an unset state.
boolean
hasShortTermIlluminationStability () Checks whether the ShortTermIlluminationStability attribute is present.
void
setLongTermIlluminationStability (float value, boolean validate) Sets the value of the LongTermIlluminationStability attribute.
void
setLongTermIlluminationStability (float value) Sets the value of the LongTermIlluminationStability attribute.
float
getLongTermIlluminationStability () Returns the value of the LongTermIlluminationStability attribute.
void
resetLongTermIlluminationStability () Resets the LongTermIlluminationStability attribute to an unset state.
boolean
hasLongTermIlluminationStability () Checks whether the LongTermIlluminationStability attribute is present.
void
setIlluminationLinearity (float value, boolean validate) Sets the value of the IlluminationLinearity attribute.
void
setIlluminationLinearity (float value) Sets the value of the IlluminationLinearity attribute.
float
getIlluminationLinearity () Returns the value of the IlluminationLinearity attribute.
void
resetIlluminationLinearity () Resets the IlluminationLinearity attribute to an unset state.
boolean
hasIlluminationLinearity () Checks whether the IlluminationLinearity attribute is present.
void
setObservedIrradianceAtSample (float value, boolean validate) Sets the value of the ObservedIrradianceAtSample attribute.
void
setObservedIrradianceAtSample (float value) Sets the value of the ObservedIrradianceAtSample attribute.
float
getObservedIrradianceAtSample () Returns the value of the ObservedIrradianceAtSample attribute.
void
resetObservedIrradianceAtSample () Resets the ObservedIrradianceAtSample attribute to an unset state.
boolean
hasObservedIrradianceAtSample () Checks whether the ObservedIrradianceAtSample attribute is present.
void
setObservedIrradianceAtSampleUnit (UnitsIrradiance_Type value, boolean validate) Sets the value of the ObservedIrradianceAtSampleUnit attribute.
void
setObservedIrradianceAtSampleUnit (UnitsIrradiance_Type value) Sets the value of the ObservedIrradianceAtSampleUnit attribute.
UnitsIrradiance_Type
getObservedIrradianceAtSampleUnit () Returns the value of the ObservedIrradianceAtSampleUnit attribute.
void
resetObservedIrradianceAtSampleUnit () Resets the ObservedIrradianceAtSampleUnit attribute to an unset state.
boolean
hasObservedIrradianceAtSampleUnit () Checks whether the optional ObservedIrradianceAtSampleUnit attribute is present.
void
setObservedIrradianceVariance (float value, boolean validate) Sets the value of the ObservedIrradianceVariance attribute.
void
setObservedIrradianceVariance (float value) Sets the value of the ObservedIrradianceVariance attribute.
float
getObservedIrradianceVariance () Returns the value of the ObservedIrradianceVariance attribute.
void
resetObservedIrradianceVariance () Resets the ObservedIrradianceVariance attribute to an unset state.
boolean
hasObservedIrradianceVariance () Checks whether the ObservedIrradianceVariance attribute is present.
ExcitationCalibration
__internal_create (long cPtr, boolean own)
ExcitationCalibration
fromBase (NBOBaseClass base) Cast a NBOBaseClass to a ExcitationCalibration .
Protected Functions
Additional inherited members
Public Functions inherited from com.inscoper.nbo.IntensityCalibration_Type
Name
IntensityCalibration_Type ()
void
setID (LSID_Type value, boolean validate) Sets the value of the ID attribute.
void
setID (LSID_Type value) Sets the value of the ID attribute.
LSID_Type
getID () Returns the value of the ID attribute.
void
resetID () Resets the ID attribute to an unset state.
boolean
hasID () Checks whether the optional ID attribute is present.
void
setDate (String value, boolean validate) Sets the value of the Date attribute.
void
setDate (String value) Sets the value of the Date attribute.
String
getDate () Returns the value of the Date attribute.
void
resetDate () Resets the Date attribute to an unset state.
boolean
hasDate () Checks whether the Date attribute is present.
void
setSampleSize (PositiveInt_Type value, boolean validate) Sets the value of the SampleSize attribute.
void
setSampleSize (PositiveInt_Type value) Sets the value of the SampleSize attribute.
PositiveInt_Type
getSampleSize () Returns the value of the SampleSize attribute.
void
resetSampleSize () Resets the SampleSize attribute to an unset state.
boolean
hasSampleSize () Checks whether the optional SampleSize attribute is present.
void
setMethod (String value, boolean validate) Sets the value of the Method attribute.
void
setMethod (String value) Sets the value of the Method attribute.
String
getMethod () Returns the value of the Method attribute.
void
resetMethod () Resets the Method attribute to an unset state.
boolean
hasMethod () Checks whether the Method attribute is present.
void
setIntensityCalibrationToolRef_List (IntensityCalibration_Type_InlineIntensityCalibrationToolRefVector value, boolean validate) Sets the list of IntensityCalibrationToolRef elements.
void
setIntensityCalibrationToolRef_List (IntensityCalibration_Type_InlineIntensityCalibrationToolRefVector value) Sets the list of IntensityCalibrationToolRef elements.
IntensityCalibration_Type_InlineIntensityCalibrationToolRefVector
getIntensityCalibrationToolRef_List () Returns the list of IntensityCalibrationToolRef elements.
void
addToIntensityCalibrationToolRef_List (IntensityCalibration_Type_InlineIntensityCalibrationToolRef value, boolean validate) Adds a new IntensityCalibrationToolRef element to this object.
void
addToIntensityCalibrationToolRef_List (IntensityCalibration_Type_InlineIntensityCalibrationToolRef value) Adds a new IntensityCalibrationToolRef element to this object.
void
clearIntensityCalibrationToolRef_List () Clear the list of IntensityCalibrationToolRef.
void
setIntensityCalibrationReport_List (FileAnnotation_TypeVector value, boolean validate) Sets the list of IntensityCalibrationReport elements.
void
setIntensityCalibrationReport_List (FileAnnotation_TypeVector value) Sets the list of IntensityCalibrationReport elements.
FileAnnotation_TypeVector
getIntensityCalibrationReport_List () Returns the list of IntensityCalibrationReport elements.
void
addToIntensityCalibrationReport_List (FileAnnotation_Type value, boolean validate) Adds a new IntensityCalibrationReport element to this object.
void
addToIntensityCalibrationReport_List (FileAnnotation_Type value) Adds a new IntensityCalibrationReport element to this object.
void
clearIntensityCalibrationReport_List () Clear the list of IntensityCalibrationReport.
void
setCalibrationSoftware_List (CalibrationSoftwareVector value, boolean validate) Sets the list of CalibrationSoftware elements.
void
setCalibrationSoftware_List (CalibrationSoftwareVector value) Sets the list of CalibrationSoftware elements.
CalibrationSoftwareVector
getCalibrationSoftware_List () Returns the list of CalibrationSoftware elements.
void
addToCalibrationSoftware_List (CalibrationSoftware value, boolean validate) Adds a new CalibrationSoftware element to this object.
void
addToCalibrationSoftware_List (CalibrationSoftware value) Adds a new CalibrationSoftware element to this object.
void
clearCalibrationSoftware_List () Clear the list of CalibrationSoftware .
void
setAnnotationRef (IntensityCalibration_Type_InlineAnnotationRef value, boolean validate) Sets the value of the AnnotationRef element.
void
setAnnotationRef (IntensityCalibration_Type_InlineAnnotationRef value) Sets the value of the AnnotationRef element.
IntensityCalibration_Type_InlineAnnotationRef
getAnnotationRef () Returns the value of the AnnotationRef element.
void
resetAnnotationRef () Resets the AnnotationRef element to an unset state.
boolean
hasAnnotationRef () Checks whether the optional AnnotationRef element is present.
StringSet
getDateAllowedValues () Returns the allowed values for this attribut.
StringSet
getMethodAllowedValues () Returns the allowed values for this attribut.
Protected Functions inherited from com.inscoper.nbo.IntensityCalibration_Type
Protected Functions inherited from com.inscoper.nbo.NBOBaseClass
Detailed Description
public class com . inscoper . nbo . ExcitationCalibration ;
Represents the XML element ExcitationCalibration .
This element describes the procedure used to measure and calibrate the Wavelength and Irradiance of the Excitation Light Source used to Acquire this experimental Image and the resulting calibration measurements.
Public Functions Documentation
function delete function ExcitationCalibration function getTypeName function getXMLName function getNBOType function getChildren function getSubElements function fromJsonFile
public void fromJsonFile (
String path ,
boolean validate
)
Populates this object from a JSON file.
Parameters :
path The path to the JSON file
validate If true, validates constraints on value. Default is true.
Reimplements : com.inscoper.nbo.IntensityCalibration_Type.fromJsonFile
function fromJsonFile function fromJsonString
public void fromJsonString (
String json_string ,
boolean validate
)
Populates this object from a JSON string.
Parameters :
json_string The JSON content as a string
validate If true, validates constraints on value. Default is true.
Reimplements : com.inscoper.nbo.IntensityCalibration_Type.fromJsonString
function fromJsonString function fromXmlFile
public void fromXmlFile (
String path ,
boolean validate
)
Populates this object from a XML file.
Parameters :
path The path to the XML file
validate If true, validates constraints on value. Default is true.
Reimplements : com.inscoper.nbo.IntensityCalibration_Type.fromXmlFile
function fromXmlFile function fromXmlString
public void fromXmlString (
String xml_string ,
boolean validate
)
Populates this object from a XML string.
Parameters :
xml_string The XML content as a string
validate If true, validates constraints on value. Default is true.
Reimplements : com.inscoper.nbo.IntensityCalibration_Type.fromXmlString
function fromXmlString function toXmlFile
public void toXmlFile (
String filename ,
boolean validate
)
Serializes this object to an XML file.
Parameters :
filename The path to the output XML file
validate If true, validates constraints on value. Default is true.
Reimplements : com.inscoper.nbo.IntensityCalibration_Type.toXmlFile
function toXmlFile function toXmlString
public String toXmlString (
boolean validate
)
Serializes this object to an XML string.
Parameters :
validate If true, validates constraints on value. Default is true.
Return : A string containing the XML representation of this object
Reimplements : com.inscoper.nbo.IntensityCalibration_Type.toXmlString
function toXmlString function setSpinningDiskInLightPath
public void setSpinningDiskInLightPath (
boolean value ,
boolean validate
)
Sets the value of the SpinningDiskInLightPath attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
In case of a Spinning Disk Confocal Microscope, this field records whether (True) or not (False) the Spinning Disk was placed in the Light Path during this Calibration Procedure.
function setSpinningDiskInLightPath
public void setSpinningDiskInLightPath (
boolean value
)
Sets the value of the SpinningDiskInLightPath attribute.
Parameters :
In case of a Spinning Disk Confocal Microscope, this field records whether (True) or not (False) the Spinning Disk was placed in the Light Path during this Calibration Procedure.
function getSpinningDiskInLightPath
public boolean getSpinningDiskInLightPath ()
Returns the value of the SpinningDiskInLightPath attribute.
Return : The value of the attribute
In case of a Spinning Disk Confocal Microscope, this field records whether (True) or not (False) the Spinning Disk was placed in the Light Path during this Calibration Procedure.
function resetSpinningDiskInLightPath
public void resetSpinningDiskInLightPath ()
Resets the SpinningDiskInLightPath attribute to an unset state.
In case of a Spinning Disk Confocal Microscope, this field records whether (True) or not (False) the Spinning Disk was placed in the Light Path during this Calibration Procedure.
function hasSpinningDiskInLightPath
public boolean hasSpinningDiskInLightPath ()
Checks whether the SpinningDiskInLightPath attribute is present.
Return : true if the attribute has been set, false otherwise
In case of a Spinning Disk Confocal Microscope, this field records whether (True) or not (False) the Spinning Disk was placed in the Light Path during this Calibration Procedure.
function setNominalEx_Wavelength
public void setNominalEx_Wavelength (
float value ,
boolean validate
)
Sets the value of the NominalEx_Wavelength attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
In case this is different from the Excitation Wavelength of the Channel this Calibration Procedure is associated with, this field records the Nominal Peak Excitation Wavelength that is employed during this Procedure.
function setNominalEx_Wavelength
public void setNominalEx_Wavelength (
float value
)
Sets the value of the NominalEx_Wavelength attribute.
Parameters :
In case this is different from the Excitation Wavelength of the Channel this Calibration Procedure is associated with, this field records the Nominal Peak Excitation Wavelength that is employed during this Procedure.
function getNominalEx_Wavelength
public float getNominalEx_Wavelength ()
Returns the value of the NominalEx_Wavelength attribute.
Return : The value of the attribute
In case this is different from the Excitation Wavelength of the Channel this Calibration Procedure is associated with, this field records the Nominal Peak Excitation Wavelength that is employed during this Procedure.
function resetNominalEx_Wavelength
public void resetNominalEx_Wavelength ()
Resets the NominalEx_Wavelength attribute to an unset state.
In case this is different from the Excitation Wavelength of the Channel this Calibration Procedure is associated with, this field records the Nominal Peak Excitation Wavelength that is employed during this Procedure.
function hasNominalEx_Wavelength
public boolean hasNominalEx_Wavelength ()
Checks whether the NominalEx_Wavelength attribute is present.
Return : true if the attribute has been set, false otherwise
In case this is different from the Excitation Wavelength of the Channel this Calibration Procedure is associated with, this field records the Nominal Peak Excitation Wavelength that is employed during this Procedure.
function setNominalEx_WavelengthUnit
public void setNominalEx_WavelengthUnit (
UnitsLength_Type value ,
boolean validate
)
Sets the value of the NominalEx_WavelengthUnit attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
No description available in the XSD standard.
function setNominalEx_WavelengthUnit
public void setNominalEx_WavelengthUnit (
UnitsLength_Type value
)
Sets the value of the NominalEx_WavelengthUnit attribute.
Parameters :
No description available in the XSD standard.
function getNominalEx_WavelengthUnit
public UnitsLength_Type getNominalEx_WavelengthUnit ()
Returns the value of the NominalEx_WavelengthUnit attribute.
Return : The value of the attribute
No description available in the XSD standard.
function resetNominalEx_WavelengthUnit
public void resetNominalEx_WavelengthUnit ()
Resets the NominalEx_WavelengthUnit attribute to an unset state.
No description available in the XSD standard.
function hasNominalEx_WavelengthUnit
public boolean hasNominalEx_WavelengthUnit ()
Checks whether the optional NominalEx_WavelengthUnit attribute is present.
Return : true if the optional attribute has been set, false otherwise
No description available in the XSD standard.
function setObservedEx_Wavelength
public void setObservedEx_Wavelength (
float value ,
boolean validate
)
Sets the value of the ObservedEx_Wavelength attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
This field records the observed Peak Excitation Wavelength at the Back Objective as measured by using this Calibration Procedure.
function setObservedEx_Wavelength
public void setObservedEx_Wavelength (
float value
)
Sets the value of the ObservedEx_Wavelength attribute.
Parameters :
This field records the observed Peak Excitation Wavelength at the Back Objective as measured by using this Calibration Procedure.
function getObservedEx_Wavelength
public float getObservedEx_Wavelength ()
Returns the value of the ObservedEx_Wavelength attribute.
Return : The value of the attribute
This field records the observed Peak Excitation Wavelength at the Back Objective as measured by using this Calibration Procedure.
function resetObservedEx_Wavelength
public void resetObservedEx_Wavelength ()
Resets the ObservedEx_Wavelength attribute to an unset state.
This field records the observed Peak Excitation Wavelength at the Back Objective as measured by using this Calibration Procedure.
function hasObservedEx_Wavelength
public boolean hasObservedEx_Wavelength ()
Checks whether the ObservedEx_Wavelength attribute is present.
Return : true if the attribute has been set, false otherwise
This field records the observed Peak Excitation Wavelength at the Back Objective as measured by using this Calibration Procedure.
function setObservedEx_WavelengthUnit
public void setObservedEx_WavelengthUnit (
UnitsLength_Type value ,
boolean validate
)
Sets the value of the ObservedEx_WavelengthUnit attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
No description available in the XSD standard.
function setObservedEx_WavelengthUnit
public void setObservedEx_WavelengthUnit (
UnitsLength_Type value
)
Sets the value of the ObservedEx_WavelengthUnit attribute.
Parameters :
No description available in the XSD standard.
function getObservedEx_WavelengthUnit
public UnitsLength_Type getObservedEx_WavelengthUnit ()
Returns the value of the ObservedEx_WavelengthUnit attribute.
Return : The value of the attribute
No description available in the XSD standard.
function resetObservedEx_WavelengthUnit
public void resetObservedEx_WavelengthUnit ()
Resets the ObservedEx_WavelengthUnit attribute to an unset state.
No description available in the XSD standard.
function hasObservedEx_WavelengthUnit
public boolean hasObservedEx_WavelengthUnit ()
Checks whether the optional ObservedEx_WavelengthUnit attribute is present.
Return : true if the optional attribute has been set, false otherwise
No description available in the XSD standard.
function setPercentageNominalPowerSettings
public void setPercentageNominalPowerSettings (
float value ,
boolean validate
)
Sets the value of the PercentageNominalPowerSettings attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
This field records the input % Nominal Illumination Power that was set during this Calibration Procedure as by the Manufacturer.
function setPercentageNominalPowerSettings
public void setPercentageNominalPowerSettings (
float value
)
Sets the value of the PercentageNominalPowerSettings attribute.
Parameters :
This field records the input % Nominal Illumination Power that was set during this Calibration Procedure as by the Manufacturer.
function getPercentageNominalPowerSettings
public float getPercentageNominalPowerSettings ()
Returns the value of the PercentageNominalPowerSettings attribute.
Return : The value of the attribute
This field records the input % Nominal Illumination Power that was set during this Calibration Procedure as by the Manufacturer.
function resetPercentageNominalPowerSettings
public void resetPercentageNominalPowerSettings ()
Resets the PercentageNominalPowerSettings attribute to an unset state.
This field records the input % Nominal Illumination Power that was set during this Calibration Procedure as by the Manufacturer.
function hasPercentageNominalPowerSettings
public boolean hasPercentageNominalPowerSettings ()
Checks whether the PercentageNominalPowerSettings attribute is present.
Return : true if the attribute has been set, false otherwise
This field records the input % Nominal Illumination Power that was set during this Calibration Procedure as by the Manufacturer.
function setObservedIlluminationPowerAtBackOfObjective
public void setObservedIlluminationPowerAtBackOfObjective (
float value ,
boolean validate
)
Sets the value of the ObservedIlluminationPowerAtBackOfObjective attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
This field records the observed excitation Illumination Power (also known as Power Output or Illumination Intensity) as recorded at the back focal plane of the Objective by using this Calibration Procedure. In order to collect this metric it is necessary to remove the Objective .
function setObservedIlluminationPowerAtBackOfObjective
public void setObservedIlluminationPowerAtBackOfObjective (
float value
)
Sets the value of the ObservedIlluminationPowerAtBackOfObjective attribute.
Parameters :
This field records the observed excitation Illumination Power (also known as Power Output or Illumination Intensity) as recorded at the back focal plane of the Objective by using this Calibration Procedure. In order to collect this metric it is necessary to remove the Objective .
function getObservedIlluminationPowerAtBackOfObjective
public float getObservedIlluminationPowerAtBackOfObjective ()
Returns the value of the ObservedIlluminationPowerAtBackOfObjective attribute.
Return : The value of the attribute
This field records the observed excitation Illumination Power (also known as Power Output or Illumination Intensity) as recorded at the back focal plane of the Objective by using this Calibration Procedure. In order to collect this metric it is necessary to remove the Objective .
function resetObservedIlluminationPowerAtBackOfObjective
public void resetObservedIlluminationPowerAtBackOfObjective ()
Resets the ObservedIlluminationPowerAtBackOfObjective attribute to an unset state.
This field records the observed excitation Illumination Power (also known as Power Output or Illumination Intensity) as recorded at the back focal plane of the Objective by using this Calibration Procedure. In order to collect this metric it is necessary to remove the Objective .
function hasObservedIlluminationPowerAtBackOfObjective
public boolean hasObservedIlluminationPowerAtBackOfObjective ()
Checks whether the ObservedIlluminationPowerAtBackOfObjective attribute is present.
Return : true if the attribute has been set, false otherwise
This field records the observed excitation Illumination Power (also known as Power Output or Illumination Intensity) as recorded at the back focal plane of the Objective by using this Calibration Procedure. In order to collect this metric it is necessary to remove the Objective .
function setObservedIlluminationPowerAtBackObjectiveUnit
public void setObservedIlluminationPowerAtBackObjectiveUnit (
UnitsPower_Type value ,
boolean validate
)
Sets the value of the ObservedIlluminationPowerAtBackObjectiveUnit attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
No description available in the XSD standard.
function setObservedIlluminationPowerAtBackObjectiveUnit
public void setObservedIlluminationPowerAtBackObjectiveUnit (
UnitsPower_Type value
)
Sets the value of the ObservedIlluminationPowerAtBackObjectiveUnit attribute.
Parameters :
No description available in the XSD standard.
function getObservedIlluminationPowerAtBackObjectiveUnit
public UnitsPower_Type getObservedIlluminationPowerAtBackObjectiveUnit ()
Returns the value of the ObservedIlluminationPowerAtBackObjectiveUnit attribute.
Return : The value of the attribute
No description available in the XSD standard.
function resetObservedIlluminationPowerAtBackObjectiveUnit
public void resetObservedIlluminationPowerAtBackObjectiveUnit ()
Resets the ObservedIlluminationPowerAtBackObjectiveUnit attribute to an unset state.
No description available in the XSD standard.
function hasObservedIlluminationPowerAtBackObjectiveUnit
public boolean hasObservedIlluminationPowerAtBackObjectiveUnit ()
Checks whether the optional ObservedIlluminationPowerAtBackObjectiveUnit attribute is present.
Return : true if the optional attribute has been set, false otherwise
No description available in the XSD standard.
function setObseredIlluminationPowerAtSample
public void setObseredIlluminationPowerAtSample (
float value ,
boolean validate
)
Sets the value of the ObseredIlluminationPowerAtSample attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
This field records the observed excitation Illumination Power (also known as Power Output or Illumination Intensity) as recorded at the Sample (also referred to as the Front of the Objective ) by using this Calibration Procedure. This metric is typically recorded with the Objective in place.
function setObseredIlluminationPowerAtSample
public void setObseredIlluminationPowerAtSample (
float value
)
Sets the value of the ObseredIlluminationPowerAtSample attribute.
Parameters :
This field records the observed excitation Illumination Power (also known as Power Output or Illumination Intensity) as recorded at the Sample (also referred to as the Front of the Objective ) by using this Calibration Procedure. This metric is typically recorded with the Objective in place.
function getObseredIlluminationPowerAtSample
public float getObseredIlluminationPowerAtSample ()
Returns the value of the ObseredIlluminationPowerAtSample attribute.
Return : The value of the attribute
This field records the observed excitation Illumination Power (also known as Power Output or Illumination Intensity) as recorded at the Sample (also referred to as the Front of the Objective ) by using this Calibration Procedure. This metric is typically recorded with the Objective in place.
function resetObseredIlluminationPowerAtSample
public void resetObseredIlluminationPowerAtSample ()
Resets the ObseredIlluminationPowerAtSample attribute to an unset state.
This field records the observed excitation Illumination Power (also known as Power Output or Illumination Intensity) as recorded at the Sample (also referred to as the Front of the Objective ) by using this Calibration Procedure. This metric is typically recorded with the Objective in place.
function hasObseredIlluminationPowerAtSample
public boolean hasObseredIlluminationPowerAtSample ()
Checks whether the ObseredIlluminationPowerAtSample attribute is present.
Return : true if the attribute has been set, false otherwise
This field records the observed excitation Illumination Power (also known as Power Output or Illumination Intensity) as recorded at the Sample (also referred to as the Front of the Objective ) by using this Calibration Procedure. This metric is typically recorded with the Objective in place.
function setObseredIlluminationPowerAtSampleUnit
public void setObseredIlluminationPowerAtSampleUnit (
UnitsPower_Type value ,
boolean validate
)
Sets the value of the ObseredIlluminationPowerAtSampleUnit attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
No description available in the XSD standard.
function setObseredIlluminationPowerAtSampleUnit
public void setObseredIlluminationPowerAtSampleUnit (
UnitsPower_Type value
)
Sets the value of the ObseredIlluminationPowerAtSampleUnit attribute.
Parameters :
No description available in the XSD standard.
function getObseredIlluminationPowerAtSampleUnit
public UnitsPower_Type getObseredIlluminationPowerAtSampleUnit ()
Returns the value of the ObseredIlluminationPowerAtSampleUnit attribute.
Return : The value of the attribute
No description available in the XSD standard.
function resetObseredIlluminationPowerAtSampleUnit
public void resetObseredIlluminationPowerAtSampleUnit ()
Resets the ObseredIlluminationPowerAtSampleUnit attribute to an unset state.
No description available in the XSD standard.
function hasObseredIlluminationPowerAtSampleUnit
public boolean hasObseredIlluminationPowerAtSampleUnit ()
Checks whether the optional ObseredIlluminationPowerAtSampleUnit attribute is present.
Return : true if the optional attribute has been set, false otherwise
No description available in the XSD standard.
function setShortTermIlluminationStability
public void setShortTermIlluminationStability (
float value ,
boolean validate
)
Sets the value of the ShortTermIlluminationStability attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
According to ISO 21073:2019, Illumination Stability is defined as the percentage deviation of Minimum and Maximum Illumination Power from the Average Power during the time interval considered. Specifically, SATB [%] = 100x {1-[(Pmax-Pmin)/Pmax+Pmin]}, where Pmax is the maximum laser power recorded during the time interval; and Pmin is the minimum laser power recorded during the time interval. This field records the Short Term Illumination Stability recorded during this Calibration Procedure by measuring Illumination Power every second for a time interval of 5 min of continuous illumination.
function setShortTermIlluminationStability
public void setShortTermIlluminationStability (
float value
)
Sets the value of the ShortTermIlluminationStability attribute.
Parameters :
According to ISO 21073:2019, Illumination Stability is defined as the percentage deviation of Minimum and Maximum Illumination Power from the Average Power during the time interval considered. Specifically, SATB [%] = 100x {1-[(Pmax-Pmin)/Pmax+Pmin]}, where Pmax is the maximum laser power recorded during the time interval; and Pmin is the minimum laser power recorded during the time interval. This field records the Short Term Illumination Stability recorded during this Calibration Procedure by measuring Illumination Power every second for a time interval of 5 min of continuous illumination.
function getShortTermIlluminationStability
public float getShortTermIlluminationStability ()
Returns the value of the ShortTermIlluminationStability attribute.
Return : The value of the attribute
According to ISO 21073:2019, Illumination Stability is defined as the percentage deviation of Minimum and Maximum Illumination Power from the Average Power during the time interval considered. Specifically, SATB [%] = 100x {1-[(Pmax-Pmin)/Pmax+Pmin]}, where Pmax is the maximum laser power recorded during the time interval; and Pmin is the minimum laser power recorded during the time interval. This field records the Short Term Illumination Stability recorded during this Calibration Procedure by measuring Illumination Power every second for a time interval of 5 min of continuous illumination.
function resetShortTermIlluminationStability
public void resetShortTermIlluminationStability ()
Resets the ShortTermIlluminationStability attribute to an unset state.
According to ISO 21073:2019, Illumination Stability is defined as the percentage deviation of Minimum and Maximum Illumination Power from the Average Power during the time interval considered. Specifically, SATB [%] = 100x {1-[(Pmax-Pmin)/Pmax+Pmin]}, where Pmax is the maximum laser power recorded during the time interval; and Pmin is the minimum laser power recorded during the time interval. This field records the Short Term Illumination Stability recorded during this Calibration Procedure by measuring Illumination Power every second for a time interval of 5 min of continuous illumination.
function hasShortTermIlluminationStability
public boolean hasShortTermIlluminationStability ()
Checks whether the ShortTermIlluminationStability attribute is present.
Return : true if the attribute has been set, false otherwise
According to ISO 21073:2019, Illumination Stability is defined as the percentage deviation of Minimum and Maximum Illumination Power from the Average Power during the time interval considered. Specifically, SATB [%] = 100x {1-[(Pmax-Pmin)/Pmax+Pmin]}, where Pmax is the maximum laser power recorded during the time interval; and Pmin is the minimum laser power recorded during the time interval. This field records the Short Term Illumination Stability recorded during this Calibration Procedure by measuring Illumination Power every second for a time interval of 5 min of continuous illumination.
function setLongTermIlluminationStability
public void setLongTermIlluminationStability (
float value ,
boolean validate
)
Sets the value of the LongTermIlluminationStability attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
According to ISO 21073:2019, Illumination Stability is defined as the percentage deviation of Minimum and Maximum Illumination Power from the Average Power during the time interval considered. Specifically, SATB [%] = 100x {1-[(Pmax-Pmin)/Pmax+Pmin]}, where Pmax is the maximum laser power recorded during the time interval; and Pmin is the minimum laser power recorded during the time interval. This field records the Long Term Illumination Stability recorded during this Calibration Procedure by measuring Illumination Power every 30 s for one second for a time interval of 120 min of continuous illumination.
function setLongTermIlluminationStability
public void setLongTermIlluminationStability (
float value
)
Sets the value of the LongTermIlluminationStability attribute.
Parameters :
According to ISO 21073:2019, Illumination Stability is defined as the percentage deviation of Minimum and Maximum Illumination Power from the Average Power during the time interval considered. Specifically, SATB [%] = 100x {1-[(Pmax-Pmin)/Pmax+Pmin]}, where Pmax is the maximum laser power recorded during the time interval; and Pmin is the minimum laser power recorded during the time interval. This field records the Long Term Illumination Stability recorded during this Calibration Procedure by measuring Illumination Power every 30 s for one second for a time interval of 120 min of continuous illumination.
function getLongTermIlluminationStability
public float getLongTermIlluminationStability ()
Returns the value of the LongTermIlluminationStability attribute.
Return : The value of the attribute
According to ISO 21073:2019, Illumination Stability is defined as the percentage deviation of Minimum and Maximum Illumination Power from the Average Power during the time interval considered. Specifically, SATB [%] = 100x {1-[(Pmax-Pmin)/Pmax+Pmin]}, where Pmax is the maximum laser power recorded during the time interval; and Pmin is the minimum laser power recorded during the time interval. This field records the Long Term Illumination Stability recorded during this Calibration Procedure by measuring Illumination Power every 30 s for one second for a time interval of 120 min of continuous illumination.
function resetLongTermIlluminationStability
public void resetLongTermIlluminationStability ()
Resets the LongTermIlluminationStability attribute to an unset state.
According to ISO 21073:2019, Illumination Stability is defined as the percentage deviation of Minimum and Maximum Illumination Power from the Average Power during the time interval considered. Specifically, SATB [%] = 100x {1-[(Pmax-Pmin)/Pmax+Pmin]}, where Pmax is the maximum laser power recorded during the time interval; and Pmin is the minimum laser power recorded during the time interval. This field records the Long Term Illumination Stability recorded during this Calibration Procedure by measuring Illumination Power every 30 s for one second for a time interval of 120 min of continuous illumination.
function hasLongTermIlluminationStability
public boolean hasLongTermIlluminationStability ()
Checks whether the LongTermIlluminationStability attribute is present.
Return : true if the attribute has been set, false otherwise
According to ISO 21073:2019, Illumination Stability is defined as the percentage deviation of Minimum and Maximum Illumination Power from the Average Power during the time interval considered. Specifically, SATB [%] = 100x {1-[(Pmax-Pmin)/Pmax+Pmin]}, where Pmax is the maximum laser power recorded during the time interval; and Pmin is the minimum laser power recorded during the time interval. This field records the Long Term Illumination Stability recorded during this Calibration Procedure by measuring Illumination Power every 30 s for one second for a time interval of 120 min of continuous illumination.
function setIlluminationLinearity
public void setIlluminationLinearity (
float value ,
boolean validate
)
Sets the value of the IlluminationLinearity attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
This field captures the Linear Correlation Coefficient of observed Output Illumination Power response to different input Power settings, as measured at the back of the Objective .
function setIlluminationLinearity
public void setIlluminationLinearity (
float value
)
Sets the value of the IlluminationLinearity attribute.
Parameters :
This field captures the Linear Correlation Coefficient of observed Output Illumination Power response to different input Power settings, as measured at the back of the Objective .
function getIlluminationLinearity
public float getIlluminationLinearity ()
Returns the value of the IlluminationLinearity attribute.
Return : The value of the attribute
This field captures the Linear Correlation Coefficient of observed Output Illumination Power response to different input Power settings, as measured at the back of the Objective .
function resetIlluminationLinearity
public void resetIlluminationLinearity ()
Resets the IlluminationLinearity attribute to an unset state.
This field captures the Linear Correlation Coefficient of observed Output Illumination Power response to different input Power settings, as measured at the back of the Objective .
function hasIlluminationLinearity
public boolean hasIlluminationLinearity ()
Checks whether the IlluminationLinearity attribute is present.
Return : true if the attribute has been set, false otherwise
This field captures the Linear Correlation Coefficient of observed Output Illumination Power response to different input Power settings, as measured at the back of the Objective .
function setObservedIrradianceAtSample
public void setObservedIrradianceAtSample (
float value ,
boolean validate
)
Sets the value of the ObservedIrradianceAtSample attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
Observed mean excitation light irradiance (radiant power per unit area) as measured at the sample plane over the Field of View (FOV).
function setObservedIrradianceAtSample
public void setObservedIrradianceAtSample (
float value
)
Sets the value of the ObservedIrradianceAtSample attribute.
Parameters :
Observed mean excitation light irradiance (radiant power per unit area) as measured at the sample plane over the Field of View (FOV).
function getObservedIrradianceAtSample
public float getObservedIrradianceAtSample ()
Returns the value of the ObservedIrradianceAtSample attribute.
Return : The value of the attribute
Observed mean excitation light irradiance (radiant power per unit area) as measured at the sample plane over the Field of View (FOV).
function resetObservedIrradianceAtSample
public void resetObservedIrradianceAtSample ()
Resets the ObservedIrradianceAtSample attribute to an unset state.
Observed mean excitation light irradiance (radiant power per unit area) as measured at the sample plane over the Field of View (FOV).
function hasObservedIrradianceAtSample
public boolean hasObservedIrradianceAtSample ()
Checks whether the ObservedIrradianceAtSample attribute is present.
Return : true if the attribute has been set, false otherwise
Observed mean excitation light irradiance (radiant power per unit area) as measured at the sample plane over the Field of View (FOV).
function setObservedIrradianceAtSampleUnit
public void setObservedIrradianceAtSampleUnit (
UnitsIrradiance_Type value ,
boolean validate
)
Sets the value of the ObservedIrradianceAtSampleUnit attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
No description available in the XSD standard.
function setObservedIrradianceAtSampleUnit
public void setObservedIrradianceAtSampleUnit (
UnitsIrradiance_Type value
)
Sets the value of the ObservedIrradianceAtSampleUnit attribute.
Parameters :
No description available in the XSD standard.
function getObservedIrradianceAtSampleUnit
public UnitsIrradiance_Type getObservedIrradianceAtSampleUnit ()
Returns the value of the ObservedIrradianceAtSampleUnit attribute.
Return : The value of the attribute
No description available in the XSD standard.
function resetObservedIrradianceAtSampleUnit
public void resetObservedIrradianceAtSampleUnit ()
Resets the ObservedIrradianceAtSampleUnit attribute to an unset state.
No description available in the XSD standard.
function hasObservedIrradianceAtSampleUnit
public boolean hasObservedIrradianceAtSampleUnit ()
Checks whether the optional ObservedIrradianceAtSampleUnit attribute is present.
Return : true if the optional attribute has been set, false otherwise
No description available in the XSD standard.
function setObservedIrradianceVariance
public void setObservedIrradianceVariance (
float value ,
boolean validate
)
Sets the value of the ObservedIrradianceVariance attribute.
Parameters :
value The value to set
validate If true, validates constraints on value. Default is true.
Observed excitation light irradiance (radiant power per unit area) variation over the Field of View (FOV).
function setObservedIrradianceVariance
public void setObservedIrradianceVariance (
float value
)
Sets the value of the ObservedIrradianceVariance attribute.
Parameters :
Observed excitation light irradiance (radiant power per unit area) variation over the Field of View (FOV).
function getObservedIrradianceVariance
public float getObservedIrradianceVariance ()
Returns the value of the ObservedIrradianceVariance attribute.
Return : The value of the attribute
Observed excitation light irradiance (radiant power per unit area) variation over the Field of View (FOV).
function resetObservedIrradianceVariance
public void resetObservedIrradianceVariance ()
Resets the ObservedIrradianceVariance attribute to an unset state.
Observed excitation light irradiance (radiant power per unit area) variation over the Field of View (FOV).
function hasObservedIrradianceVariance
public boolean hasObservedIrradianceVariance ()
Checks whether the ObservedIrradianceVariance attribute is present.
Return : true if the attribute has been set, false otherwise
Observed excitation light irradiance (radiant power per unit area) variation over the Field of View (FOV).
function __internal_create function fromBase Protected Functions Documentation
function ExcitationCalibration function swigSetCMemOwn function finalize function getCPtr
protected static long getCPtr (
ExcitationCalibration obj
)
Updated on 2026-08-31 at 13:34:07 +0200